    High Pressure Fire Extinguishing Systems

    XLPE Insulated Power Cables

    600/1000V grade, plain annealed copper conductor. XLPE insulated, multicore cables laid up and inner sheathed with PVC, round galvanized steel wire armoured for multi cores and aluminium wire armoured for single cores and outer jacket with PVC.

    High Pressure Fire Extinguishing Systems

    LSF Insulated Power Cables

    LSF is an abbreviation used for Low Smoke and Fumes compound. It is used in special applications where the cable is required to emit low smoke and no halogen acid gases in the event of a fire. With low smoke emission the exit signs are clearly visible to people for escape. As this material does not contain halogens, it does not give off acidic gases when burning. The same compound is also known by following abbreviations – LSZH and/or LSOH, both standing for Low Smoke Zero Halogen.

    High Pressure Fire Extinguishing Systems

    PVC Building Wires

    PVC building wires are used for indoor fixed installation in dry locations, distribution in conduits as well as in steel support brackets and equipment wiring. Working voltage up to 450/750 V and available in standard length of 100 yards on coil.

    High Pressure Fire Extinguishing Systems

    Low Smoke Fumes Cables

    We supply a comprehensive range of low smoke fumes cables for applications where the cable is required to emit low smoke and no halogen acid gases in the event of a fire. With low smoke emission the exit signs are clearly visible to people for escape. As this material does not contain halogens it does not give off acidic gases when burning. The same compound is also known by following abbreviations – LSZH and/or LSOH, both standing for Low Smoke Zero Halogen.

    High Pressure Fire Extinguishing Systems

    XLPE Insulated Fire Resistant LV Power Cables

    These cables are meant for maintaining circuit integrity under fire condition for 3 hours (tested for 3 hours at 950o C temperature). 600/1000V grade, plan annealed copper conductor, glass mica tapped, XLPE insulated, multi-core cables laid up and inner sheathed with LSF (or LSOH/LSZH), round galvanized steel wire armoured and outer jacket with LSF (or LSOH/LSZH). Specifications: BS7846 (Category F2) and BS 6387 (Category, C, W & Z).

    High Pressure Fire Extinguishing Systems

    Rubber

    Rubber flexible cables are designed to provide excellent flexibility during usage. These cables can withstand weather, medium mechanical and thermal stress. They exhibit very good oil resistance property.

    High Pressure Fire Extinguishing Systems

    Medium Voltage Cables

    IEC 60502 part 2, BS 6622, BS 7835 as per Iraq specifications or any other international specification and/or customer specification.

    Specification

    • Single Core Unarmoured
    • Single Core Aluminum Wire Armoured
    • Three Core Unarmoured
    • Three Core Steel Wire Armoured
    • Three Core Steel Tape Armoured
    • Range: 1C x 25 mm² to 1C x 1000 mm² 3C x 25 mm² to 3C x 400 mm²
    High Pressure Fire Extinguishing Systems

    PVC cable

    PVC cables are used for domestic cooking and heating appliances, provided that the cable does not come in contact with the heating elements. Temperature rating: +50C up to + 70C

    High Pressure Fire Extinguishing Systems

    Panel Wires

    These cables are used for wiring of switch, control, metering, relay and instrument panels of power switchgear and for internal connections in rectifier equipment, motor starters and controllers.