Scientechnic | empowering tomorrow | UAE

Make An Enquiry

    Medium Voltage Switchgear Panels 

    Our medium voltage switchgear panels are tailored to meet local requirements and standards.

    Filter by
    High Pressure Fire Extinguishing Systems

    Gas-insulated Switchgear 8DA10 – Single Busbar

    • Up to 40.5 kV, 40 kA (3s), 5000 A busbar, 2500 A feeder
    • Metal-enclosed
    • Single-busbar System (8DA10)
    • Gas-insulated
    • Hermetically enclosed
    • Factory-assembled, type-tested switchgear according IEC 62 271-200
    High Pressure Fire Extinguishing Systems

    Gas-insulated Switchgear NX PLUS C

    • Up to 17.5 kV, 31.5 kA, 2500A busbar, 2500A feeder Up to 24 kV, 25 kA, 2500A busbar, 2000A feeder
    • Metal enclosed
    • Single busbar
    • Gas-insulated
    • Hermetically enclosed
    • Factory-assembled, type-tested switchgear according IEC 62 271-200
    High Pressure Fire Extinguishing Systems

    Air-insulated Switchgear SIMOSEC

    • Up to 24 kV, 25 kA, 1250 A busbar, 1250 A feeders
    • Metal-enclosed
    • Single busbar
    • Air-insulated technology combined with a gas-insulated switching function
    • Factory-assembled, type-tested switchgear according to IEC 62271-200
    High Pressure Fire Extinguishing Systems

    Gas-insulated Switchgear 8DJH

    • Up to 24 kV
    • Up to 25 kA
    • Up to 630A
    • Single busbar
    • Type-tested
    • Metal enclosed
    • Climate independent
    • Maintenance free
    • Individual panels and block versions
    • No gas work at site
    • Fast and easy to install
    High Pressure Fire Extinguishing Systems

    Gas-insulated Switchgear 8DJH36

    • Up to 36 kV
    • Up to 20 kA
    • Up to 630A
    • Single busbar
    • Type-tested
    • Metal enclosed
    • Climate independent
    • Maintenance free
    • Individual panels and block versions
    • No gas work at site
    • Fast and easy to install
    High Pressure Fire Extinguishing Systems

    Air-insulated Switchgear NXAIR Family

    • Up to 17.5 kV / 50 kA / 4000A
    • Up to 24 kV / 25 kA / 2500A
    • Factory-assembled, type-tested switchgear according to IEC62271-200
    • Metal enclosed
    • Loss of service continuity category: LSC 2B
    • Partition class: PM
    • Internal arc classified switchgear according to IAC A FLR for 1s arc duration
    • Compact design
    • Air as insulating medium is always available
    • Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches inside the panel
    • Single busbar, Duplex-switchgear
    • Withdrawable vacuum circuit-breaker and vacuum contactor
    • Platform concept worldwide, local manufacturing presence
    • Use of standardized devices and of maintenance-free vacuum circuit-breakers or vacuum contactors
    • Type-test of earthing switch, vacuum circuit-breaker or vacuum contactor in the panel
    • Cable testing without isolating the busbar
    • All operations with high-voltage door closed
    • Unambiguous position indicators and control elements as standard on the high-voltage door
    • Maximum security of operation by self-explaining operating logic
    • Maintenance interval > 10 years
    High Pressure Fire Extinguishing Systems

    Gas-insulated Switchgear 8DB10 – Double Busbar

    • Up to 40.5 kV, 40 kA (3s), 5000 A busbar, 2500A feeder
    • Metal-enclosed
    • Double-busbar System (8DB10)
    • Gas-insulated
    • Hermetically enclosed
    • Factory-assembled, type-tested switchgear according IEC 62 271-200